Breathable High Performance Gowns

MICROCOOL* Breathable High Performance Specialty Surgical Gown

  • HALYARD* MICROCOOL* Gown meets both the AAMI Level 4 Liquid Barrier Standard and ASTM F1670 and ASTM F1671 standards for resistance of materials used in protective clothing1,2 
  • Meets the ASTM F1671 standard for bacteriophage penetration, as well as the European Norms (ENISO 22610) for resistance to wet microbial penetration2,3 
  • Meets the ISO standard for ignition resistance (ISO 11810-1 Class I1-21—No ignition)2 
  • Meets ASTM D4966 for abrasion resistance, and produces fewer than 20 particles of lint at the 10-micron level on the Gelbo lint test2
  • HALYARD* MICROCOOL* fabric allows moisture vapor to pass through almost instantly, compared to competitive gown materials, as measured by the Moisture Vapor Transfer test4 
  • Raglan sleeves
  • Adjustable neckline
  • Specialty options for seated procedures
  • Generous cut
  • Sterile and non-sterile options available

1Meets AAMI level 4 Liquid Barrier Standard and ANSI/AAMI PB70: 2003 Liquid barrier performance and classification of protective apparel and drapes intended for use in healthcare facilities.

2Per Kimberly-Clark product specifications

3MICROCOOL* Surgical gowns pass ASTM 1671 Standard Test Method for resistance of materials used in protective clothing to penetration of bloodborne pathogens using PHI-X 174 bacteriophage penetration as a test system, and meets EN ISO 22610.

4Data on file, Kimberly-Clark Health Care

MICROCOOL* Breathable High Performance Specialty Surgical Gown Image shown for reference purposes only. Actual product appearance may vary.

  • HALYARD* MICROCOOL* Gown meets both the AAMI Level 4 Liquid Barrier Standard and ASTM F1670 and ASTM F1671 standards for resistance of materials used in protective clothing1,2 
  • Meets the ASTM F1671 standard for bacteriophage penetration, as well as the European Norms (ENISO 22610) for resistance to wet microbial penetration2,3 
  • Meets the ISO standard for ignition resistance (ISO 11810-1 Class I1-21—No ignition)2 
  • Meets ASTM D4966 for abrasion resistance, and produces fewer than 20 particles of lint at the 10-micron level on the Gelbo lint test2
  • HALYARD* MICROCOOL* fabric allows moisture vapor to pass through almost instantly, compared to competitive gown materials, as measured by the Moisture Vapor Transfer test4 
  • Raglan sleeves
  • Adjustable neckline
  • Specialty options for seated procedures
  • Generous cut
  • Sterile and non-sterile options available

1Meets AAMI level 4 Liquid Barrier Standard and ANSI/AAMI PB70: 2003 Liquid barrier performance and classification of protective apparel and drapes intended for use in healthcare facilities.

2Per Kimberly-Clark product specifications

3MICROCOOL* Surgical gowns pass ASTM 1671 Standard Test Method for resistance of materials used in protective clothing to penetration of bloodborne pathogens using PHI-X 174 bacteriophage penetration as a test system, and meets EN ISO 22610.

4Data on file, Kimberly-Clark Health Care

Description

HALYARD* MICROCOOL* Breathable High Performance Surgical Gown

The new HALYARD* MICROCOOL* Breathable High Performance Surgical Gown is the result of years of research to make MICROCOOL* more cool and protective than ever. Halyard Health has a long heritage of medical fabric leadership, with over 650 US and international patents for advanced non-woven fabrics. 

Patented Microporous Fabric
  • Soft spunbound outer layer
  • Proprietary breathable fabric
  • SMS fabric inner liner layer

HALYARD* MICROCOOL* Gowns meet the AAMI Level 4 liquid barrier standard1 

The Association for the Advancement of Medical Instrumentation (AAMI) developed the liquid barrier standard to assist healthcare personnel in the selection and use of surgical gowns, drapes and other protective apparel. MICROCOOL* Gowns are Level 4, the highest barrier protection rating available for gowns. HALYARD* MICROCOOL* Breathable High Performance Surgical Gowns provide Level 4 liquid barrier in zones A, B, and C.2,3 For surgical gowns, the critical zones are, at a minimum, the front area of the gown from chest to knees (area A) and the sleeves from the cuff to above the elbow (area B). The standard requires that the entire front of a surgical gown (Areas A, B, and C) provide a liquid barrier of at least Level 1. The back of the gown (area D) may be non-protective. 

100% Landfill free

HALYARD* MICROCOOL* Gowns are produced in facilities dedicated to cleaner manufacturing and source reduction. Every month, over 6.5 million pounds of our manufacturing waste is diverted from landfills. And the facility which manufactures our MICROCOOL* fabric is 100% landfill-free.

Clean Incineration

HALYARD* MICROCOOL* Gowns are composed of over 90% Number 5 polypropylene, which incinerates very cleanly after use.3 (Compare that to reusable gowns, which require substantial amounts of water, energy, and harsh chemicals to decontaminate and clean according to industry standards for hospital laundry.4)

PFOA-free

In compliance with EPA recommendations, HALYARD* MICROCOOL* Gowns are PFOA-free.5

Environmental Leadership

Our sustainability standards have helped Halyard Health to be repeatedly recognized for environmental leadership by the Dow Jones Sustainability Index and the Newsweek Green Rankings of the world’s most environmentally-friendly companies. 

    1. 1Meets AAMI level 4 Liquid Barrier Standard and ANSI/AAMI PB70: 2003 Liquid barrier performance and classification of protective apparel and drapes intended for use in healthcare facilities.
    2. 2Intertek Testing Services: Test Report No. G100339857CRT-001, March 22, 2011.
    3. 3Integrated Paper Services (IPS) Test Reports: 26794, Dec 3, 2010, and 24232 Sept 1, 2010.
    4. 4“A White Paper on Performance, Cost Per Use, and Environmental Impact of Single-Use and Reusable Surgical Gowns & Drapes.” McIlvaine Company, 2009.
    5. 5PFOA: Perfluorooctanoic acid; EPA recommendations to eliminate PFOA chemistry utilization. “PFOA-free” means that a product has PFOA below 20 ppb as manufactured. (Source: www.epa.gov/oppt/pfoa/pubs/stewardship/)

 

Specifications

Brand MICROCOOL*
UNSPSC Classification 42131702
Fabric SFSMS
Name MICROCOOL* Breathable High Performance Specialty Surgical Gown
Cut of Gown A-Line
Procedure Seated Procedures
Fold Book
Low Lint Yes
Neck Binding Color Red
Sleeve Type Raglan Sleeves
Specialty Gown Yes
Abrasion Resistance Meets ASTM D4966
Expected Fluid Contact High; For Lengthy, Fluid-Intensive Procedures
Flame Resistance Meets NFPA Class I and ISO 11810
AAMI Protection Level AAMI Level 4 Liquid Barrier Protection
Closure Hook-and-Loop
Gown Length Extra Long

Narrow Your Selections

1 product available

  • 72457
    Units per Case:28
    Size:XX-Large
    Includes Towel:No
    Sterile Gown:No
    See Packaging Specifications [ ]
    • Packaging Details:1 CS = 28 Units
    • Volume:1.618 FT3
    • Length:16.310 IN
    • Width:10.310 IN
    • Height:16.630 IN
    • Weight:17.070 LB
    • Cases per Layer:10 Case(s) per Layer
    • Cases per Stack:6 Case(s) per Stack
    • Layers per Stack:60 Layer(s) per Stack
    • Pallet Load Specifications:GMA: 48.000" x 40.000" x 33.260"TL: 48.000" x 40.000" x 83.150"
    • Floor Load Specifications:GMA: 47.240" x 36.930" x 49.890"SGM: 47.240" x 36.930" x 33.260"
$0.99